Rooms/Areas Space in
Max.
height
m
Theatre Classroom Banquet
Atrium 3 1.285m², Space to use 700m² 1.000 380 540

This neutral ambiance made of steel and glass is full of natural light. This makes Atrium 3 especially prestigious and enhances every event. Create your individual exhibit and catering spaces.

Directly adjacent to Atrium 3 are 21 ready-to-use show and breakout rooms.

Bitte installieren Sie Flash!/Please install Flash!


Atrium 3

Open the panoramic view of atrium 3 in a new window.

Technical Data

Size Total floor area 1,285 m²
Show and breakout rooms 21 adjoining rooms with a total of 2,173 m² gross
Studio Studio C/D with 486 m² gross
Supporting structure
  • Steel composite structure
  • Some t-beams
Floors Tiled marble floor
Room height Approx. 9.00 m, maximum usable height 6.00 m
Ceilings
  • Steel and glass construction
  • Ceiling suspensions are possible upon request
  • Suspension points may only be mounted by authorized service partners of MOC
Load capacity
  • Flooring load max. 500 kg/m²
  • Trolleys must be fitted with plastic or rubber wheels to avoid damage
  • Metal wheels or casters are not permitted
Communication
  • Connections possible via floor ducts
  • Telephone (optional)
  • Fax (optional)
  • IP connection (optional)
  • W-LAN for organizers (optional)
Electrical installation Outlets via floors ducts
Indoor climate
  • Ventilation system
  • Cooling: 10°C below outside temperature
Lighting
  • Ceiling and spotlights
  • 300 Lux
Public address/sound system
  • For announcements
  • Can be isolated to specific areas
Sanitary Facilities One WC area per section, with separate facilities for handicapped
Water connection Sanitary connections are located in the front and rear atrium area and can be installed upon request
Access and loading
  • The freight elevator and self-operated lifts can be used in the delivery zones on the ground floors and on the 2nd basement floor for the delivery of heavy and bulky goods
  • The passage to the atrium is 2.10 m wide and 2.00 m tall
  • The freight elevator must be operated by load-lift driver, to be booked for set-up and dismantling times.
Dimensions of load lift
  • Height: 2.60 m
  • Inside cabin width: 3.00 m
  • Door width: 2.50 m
  • Cabin depth: 5.37 m
  • Capacity: 8,000 kg
Dimensions self-operated lift
  • Height: 2.50 m
  • Inside cabin width: 2.00 m
  • Door width: 1.10 m
  • Cabin depth: 2.50 m
  • Capacity: 2,400 kg
Fire Protection Between the show and breakout rooms and the inside area available for stand building, a fire protection strip 4 meters in width must be kept clear; this is also the escape/rescue route. Stand covers and canopies are not permitted in the atrium for fire protection reasons.